Thông số kỹ thuật Switch PLANET WGS-804HP
Hardware | |
Network Connector | 8-Port RJ45 for 10/100/1000BASE-T |
PoE Inject Port | 4-Port with 802.3af / 802.3at PoE injector function (Port-1 to Port-4) |
Switch Architecture | Store and forward |
MAC Address Table | 8K MAC address table with auto learning function |
Data Buffer | 1Mbit |
Switch Fabric | 16Gbps / non-blocking |
Switch Throughput | 11.9Mpps@64Bytes |
Jumbo Frame | 9Kbytes |
Flow Control | IEEE 802.3x pause frame for full duplex Back pressure for half duplex |
LED Indicators | Power LED: Power (Green) PoE Power Usage LED: 30W, 60W, 90W, 120W (Green) PoE Port(Port-1 to Port-4): PoE-in-Use (Orange), LNK/ACT (Green) 10/100/1000BASE-TX Port (Port-5 to Port-8): 1000 (Green), LNK/ACT (Green) |
Connector | Removable 3-pin terminal block for power input DC power jack with 2.0mm central pole |
Power Requirements | 48~56V DC, 3A (max.) |
Power Consumption | 140 watts / 478BTU |
ESD Protection | 6KV DC |
EFT Protection | 6KV DC |
Enclosure | IP30 metal |
Dimensions (W x D x H) | 148 x 24.2 x 134 mm |
Weight | 510g |
Installation | Wall mount, magnetic wall mount and DIN-rail kit |
Power over Ethernet | |
PoE Standard | IEEE 802.3af/ 802.3at Power over Ethernet PSE |
PoE Power Supply Type | End-span |
PoE Power Output | IEEE 802.3af Standard – Per port 48V~56V DC (depending on the power supply), max. 30 watts IEEE 802.3at Standard – Per port 50V~56V DC (depending on the power supply), max. 30 watts |
Power Pin Assignment | 1/2(+), 3/6(-) |
* PoE Power Budget | 120 watts (depends on power input) |
Max. Number of Class 2 PD | 4 |
Max. Number of Class 3 PD | 4 |
Max. Number of Class 4 PD | 4 |
Standard Conformance | |
Standard Compliance | IEEE 802.3: Ethernet IEEE 802.3u: Fast Ethernet IEEE 802.3ab: Gigabit Ethernet IEEE 802.3x: Flow Control IEEE 802.3af: Power over Ethernet IEEE 802.3at: High Power over Ethernet |
Regulation Compliance | FCC Part 15 Class A, CE |
Stability Testing | IEC 60068-2-32 (Free fall) IEC 60068-2-27 (Shock) IEC 60068-2-6 (Vibration) |
Environment | |
Operating | Temperature: -10 ~ 60 degrees C Relative Humidity: 5 ~ 95% (non-condensing) |
Storage | Temperature: -20 ~ 70 degrees C Relative Humidity: 5 ~ 95% (non-condensing) |